Human TLR3 ELISA Kit
SKU: 15421225251

Human TLR3 ELISA Kit

Sale price$165.71 Regular price$184.12
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 4 - Jul 9

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Human TLR3 ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and

Product Specification

Usage Required experimental equipment:
1. Microplate reader (450nm)
2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL
3. 37°C incubator
4. Distilled or deionized water

Sample preparation and requirements:
Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results).
Weigh and mince the tissue.
Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS.
The specific volume can be adjusted according to experimental needs and recorded.
It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice.
To further lyse tissue cells, the homogenate can be sonicated or repeatedly frozen and thawed.
Finally, centrifuge the homogenate at 5000×g for 5-10 minutes, and collect the supernatant for analysis.

Cell Lysis Buffer: Adherent cells should be gently washed with pre-chilled PBS, then trypsinized and harvested by centrifugation at 1000×g for 5 minutes.
Suspension cells can be harvested directly by centrifugation.
Collected cells should be washed three times with pre-chilled PBS and resuspended in 150-200 μL of PBS per 1×10^6 cells (it is recommended to add protease inhibitors to the PBS; if the cell count is very low, reduce the PBS volume appropriately).
Disrupt the cells by repeated freezing and thawing or sonication.
Centrifuge the extract at 1500×g for 10 minutes at 2-8°C, and collect the supernatant for analysis.

Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test.

Pre-test preparation:
1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature.
2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL).
Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL.
Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each.
Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution.
Repeat this procedure for subsequent tubes.
The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube.
See the figure below for details.
3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use.
Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent).
Prepare and use immediately.
4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute.
Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent).
Prepare immediately.
5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal.
Allow to stand at room temperature until the crystals have completely dissolved before preparing).

Procedure:
1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes.
Seal the remaining strips in a ziplock bag and return to 4°C.
2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells.
Add 100 μL of universal diluent to the blank wells.
Cover with a film and incubate at 37°C for 60 minutes.
(Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate.
This will reduce the impact of matrix effects on the test results.
The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration.
It is recommended to run replicates for all test samples and standards.)
3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing.
Add 100 μL of Biotinylated Antibody Working Solution directly to each well.
Cover with a film and incubate at 37°C for 60 minutes.
4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well.
Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper.
Repeat this process three times (a plate washer can also be used).
5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well.
Cover with a film and incubate at 37°C for 30 minutes.
6. Washing: Discard the liquid and wash the plate five times as in step 4.
7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes.
8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well.
Immediately measure the OD value of each well at a wavelength of 450 nm.

Calculating experimental results:
1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor.
Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis.
2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest.
Multiply the sample concentration by the corresponding dilution factor.

Theory This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a Toll-Like Receptor 3 (TLR3) capture antibody. After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the Toll-Like Receptor 3 (TLR3) content in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration.
Source Human
Synonym Human Toll Like Receptor 3 ELISA Kit
Detection Type Double antibody sandwich method
Composition
Name 9 6 T  match   set remark
Pre-coating 96 Well plate 8 Hole ×12 Strip without
Standard 2 branch
Dilute as per instructions
Universal diluent
2×20mL
without
Concentrated biotinylated antibody ( 100× )  
120uL
Dilute as per instructions
Concentrated enzyme conjugate ( 100× )
120uL
Dilute as per instructions
20× Washing liquid
2×10mL
Dilute as per instructions
Bottom thing ( TMB )
10mL
without
Stop liquid
6mL
without
Sealing film
4 Zhang
without
Instructions
1 Share
without
Background Toll-like receptor 3 (TLR3), also known as CD283 (cluster of differentiation 283), is a protein encoded by the TLR3 gene. TLR3 is a member of the toll-like receptor family of pattern recognition receptors of the innate immune system. TLR3 recognizes double-stranded RNA in endosomes, a common feature of viral genomes internalized by macrophages and dendritic cells. As a member of the toll-like receptor (TLR) family, TLR3 plays a fundamental role in pathogen recognition and activation of innate immunity.
General Notes 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use.
2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation.
3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value.
4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue.
5. Avoid cross-contamination of reagents and specimens to prevent erroneous results.
6. Avoid direct exposure to strong light during storage and incubation.
7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit.
8. Do not use expired products, and do not mix components with different product numbers and batches.
9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized.
10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures.
Storage Temp. If the unopened kit is stored at 4°C, the shelf life is 6 months.
Test Range 0.15-10 ng/mL
Applications Tissue homogenates, cell lysates, and other biological fluids
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 15421225251

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.7 ★★★★★
Based on 458 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
C
Verified Purchase
Carl J.
Fort Morgan, US
★★★★★ 5
Great replacement wiper blades.
Size: 26"+17"+12JP(HOOK)
These were great wiper replacement for my car, very easy to install and way cheaper that buying them at a auto parts store.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 27, 2026
K
Verified Purchase
Kevin Cross
Charlottesville, US
★★★★★ 5
Impressive performance at an impressive price
Size: 26"+17"+14BP(HOOK)
I had one damaged wiper, so I decided to replace all 3 on my Subaru Outback. I have read a lot of positive information regarding "silicone" wipers, so I settled on this complete kit as it was a good value for the price and received many positive reviews. They come well packaged, yet I was concerned that the longest blade had to be bent significantly to fit in the odd shaped box. However, once installed, that blade straightened out and conformed snuggly to the contour of the windshield. True to the claim, it does take about 30 seconds to install each blade (that is if you understand the diagram and attempt to do so correctly). I had no issues and each blade snapped securely in place. They appear to be well made and durable. The design is clean and they look good on my vehicle. I've been using them for 2 months now and they work well. They clear the windshield without streaking or chatter. They seem to work as well as other types I have used. The ultimate test will be how long they last. So far, I am very pleased with my choice.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 21, 2026
K
Verified Purchase
Krazyk9gurl
Whiting, US
★★★★★ 4
Easy Installation Wipers!
Size: 26"+19"+14BP(HOOK)
Just installed them on my Outback, simple straightforward install. The instructions were simple and they seem to fit well. These wipers were more compatible than the old ones, and the appearance look like they are original! When I purchased these wipers I thought I had purchased the Rain-X wiper replacements, but they were not. These wipers seem to work when I used the windshield cleaner with the wipers. The windshield cleaning seems effortless and without any noise.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 21, 2026
C
Verified Purchase
Campgroundguy
Chelsea, US
★★★★★ 5
Great Wiper Blades, Great Price
Size: 26"+18"+16BP(D-PTB)
Perfect fit for my 2020 Subaru Outback. The blades were very well packaged and arrived in perfect condition. They clean perfectly. I have only been using them for a month, so I can’t speak to longevity. They cost less than one third the premium blades cost at the auto parts store, and work just as well.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 8, 2026
B
Verified Purchase
bartletts
Houston, US
★★★★★ 5
Easy installation, good quality!
Size: 26"+17"+14BP(HOOK)
These wiper blades are great! The packaging was impressive, and I appreciated that there is clear video instructions on Amazon. There is not 15 extra adapters, that you don’t need. Just pop open the plastic cover and slide them on. It was super easy and they fit great.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 11, 2026

recommand products